Monotonic and cyclic tests were carried out to determine strength and stiffness characteristics of 2.44 m (8 ft) long shear connections with 8 mm and 10 mm diameter self-tapping screws. The goal of this research is to compare test values of cross-laminated timber (CLT) diaphragm connections in seismic force-resisting systems...
Seismic design of wood-frame single-family dwellings’ (WFSFD) lateral force–resisting systems requires determination of the stiffness of horizontal diaphragms and shearwalls. During design, sizes and locations of shearwall openings are often changed, altering shearwall stiffness and loads and requiring a significant redesign effort. Rigid and tributary area method analyses are examined...
Ten full size (3.7 x 4.9 m) plywood roof diaphragms were constructed using metal plate connected (MPC) common and hip wood trusses or joists, typical of single-family dwelling (SFD) construction. The specimens included three gable roof slopes of 33, 67 and 100%, a hip roof of 33% slope, and a...
This paper presents the results of a test program whose goal was to better understand the contribution of individual elements to the performance of typical light-frame wood structures during tsunami loading. The intent was to be able to replicate failures in a structural engineering laboratory that were observed during laboratory...
Residential energy use is a significant contributor to greenhouse gas emissions and climate change. Reducing energy efficiency in conventional wood-framed houses are thermal bridges: direct paths that allow heat to flow through the studs instead of the insulation. One suggestion for reducing thermal bridging is the staggered stud (SS) wall....
Ten full-size (3.7×4.9m) plywood roof diaphragms were constructed using metal-plate-connected (MPC) common and hip wood trusses or joists, typical of single-family dwelling (SFD) construction. The specimens included three gable roof slopes of 33, 67, and 100%, a hip roof of 33% slope, and a flat roof, with a horizontal bottom...
The objective of this study was to develop and validate practical modeling methods for investigating load paths and system behavior in a realistic, light-frame wood structure. The modeling methods were validated against full-scale tests on sub-assemblies and an L-shaped house. The model of the L-shaped house was then modified and...
There are about 80 million single-family dwellings (SFD) in the United States,
predominantly of wood-frame construction. Of these, 68% are owner occupied. A home is
typically the largest single investment of a family, and is often not covered by earthquake
insurance, even where it is available. Of all the houses...
The objective of this study was to compare structural load path and system behavior of a light-frame (LF) and a timber frame (TF) structure. This load path analysis is part of a broader research effort that compares LF to TF residential structures. Structural analysis software was used to create a...
There are about 80 million single-family dwellings (SFDs) in the United States, predominantly of wood-frame construction. Of these, 68% are owner-occupied. A home is typically the largest single investment of a family, and is often not covered by earthquake insurance, even where it is available. Of all the houses in...