The concentration of chlorophyll in natural bodies of water is
commonly determined as a means to rapidly estimate the phytoplankton
biomass. The literature gives numerous warnings, however, as to the
problems involved with accurately determining chlorophyll
concentrations. The author's work at Crater Lake, Oregon enticed him
to explore critically the...
The concept of reducing laboratory operations in scale such that they fit on a microfluidic chip has been met with great enthusiasm. Lab-on-a-chip devices promise to be cost effective to operate due to reduced reagent consumption, have the potential to offer shorter analysis times due to their short path lengths,...
In previous work (Blakemore et al. Org. Lett. 2005, 7, 4721; Heterocycles 2006, 70, 609), successful elaborations of the lupine alkaloids (±)-α-isosparteine (dl-2) and (±)-β-isosparteine (dl-3) were realized from a common tetraoxobispidine precursor, 3,7-diallyl -2,4,6,8-tetraoxo-3,7-diazabicyclo[3.3.1]nonane (93). Herein, the tetraoxobispidine approach to lupine alkaloids was extended to a total synthesis of...
Catalysis of the racemizationof optically active phenyl
benzenethiolsulfinate, (+)-I, by (a) methylthioacetic acid (II) and (b)
a -methylthio-m-toluic acid (III) has been investigated in aqueous
dioxane and anhydrous acetonitrile at 39.6°C. Added II did not cause
any increase in the rate of racemization of (+)-I in either solvent. In
aqueous...
Detection technique that proposed utilizing electrochemically controlled, reversible ion extraction into polymeric membrane in an alternating galvanostatic/ potentiostatic mode was introduced. This method is studied in detail to comprehend the advantages of the novel sensor (pulstrode) compared to the potentiometric ion selective electrode (ISE), studies included possible applications and limitations....
A novel method for detecting the peptidase activity of clinically relevant peptidases was investigated using solid-contact electrochemical polyion sensors under chronopotentiometric control. Complete instrumental control over ion-extraction was accomplished by incorporating a lipophilic electrolyte into the ion-selective membrane; the sensors had no intrinsic ion-exchange capabilities. The sensors were used to...
This research was undertaken to develop a sensitive, selective, and rapid analytical method to measure ethyl glucuronide (EtG) and ethyl sulfate (EtS) in urine as urinary biomarkers of alcohol exposure. Large-volume injection (LVI) coupled with liquid chromatography / electrospray tandem mass spectrometry was used to eliminate the need for either...
The method of gas-phase electron diffraction is a very useful tool for determining
the geometry of a molecule in the gas-phase to a high degree of accuracy. In this thesis,
the structures of tropone and tropolone, which are similar molecules that are both based
on a 7-carbon ring, were investigated...